mvebu: LS421DE: fix low performance issue
...
The Buffalo Linkstation LS421DE isn't able to enable the Level 2 cache
(AKA Aurora cache). As of result of this, the throughput is about half of
the expected, e.g when doing network data transfers.
Fix it by adding the broken-idle property in the coherency fabric node.
Signed-off-by: Daniel González Cabanelas <dgcbueu@gmail.com >
Signed-off-by: maurerr <mariusd84@gmail.com >